Sennheiser EW 300 IEM G2 Yogurt Maker User Manual


 
46
Indications and displays on the transmitter
Modulation display
The level display for audio signal “AF” shows the modulation of the
transmitter.
When the transmitter’s audio input level is excessively high, the level display
for audio signal “AF” shows full deflection.
When the transmitter is overmodulated frequently or for an extended period
of time, the text “PEAK” (backlit in red) flashes in alternation with the
standard display.
Button backlighting
During standby operation, the ON button is backlit in red. When the
transmitter is switched on, the SET button and the ̆/̄ button are
additionally backlit in green.
Indications and displays on the receiver
Operation and battery status indication
The red LED (LOW BAT/ON) provides information on the current operating
state of the receiver:
Red LED lit up: The receiver is switched on and the capacity of the
batteries/accupack BA 2015 is sufficient.
Red LED flashing: The batteries are/the accupack BA 2015 is going flat
(LOW BAT)!
In addition, the 4-step battery status display on the display panel provides
information on the remaining battery/accupack BA 2015 capacity:
Modulation display of the receiving transmitter
The level display for audio signal “AF” shows the modulation of the
transmitter.
When the transmitter’s audio input level is excessively high (AF peak), the
receiver’s level display for audio signal “AF” shows full deflection.
»
3 segments: capacity approx. 100 %
2 segments: capacity approx. 70 %
1 segment: capacity approx. 30 %
Battery icon flashing: LOW BAT