Smeg A31G7IXIA Range User Manual


 
63
Instructions for the installer
8.2 Electrical connection
Make sure that the voltage and capacity of the power line conform to the
data shown on the plate located under the casing.
Do not remove this plate for any reason.
The plug at the end of the power cable and the wall socket must be
compatible and in compliance with current legislation on electrical
systems. Make sure that the supply line is suitably earthed.
Fit power line with an omnipolar circuit breaker with a contact opening gap
equal to or greater than 3 mm in an easily accessible position close to the
hob.
Avoid the use of adapters and shunts.
If the power cable needs to be
replaced, the wire section of the new
cable should not be less than 0.75
mm
2
(3 x 0.75 cable), with the
exception of the induction hob where
the section should be no less than
1.5 mm
2
(3 x 1.5 cable), bearing in
mind that the end piece to be
connected to the appliance must
have an earth wire (yellow-green)
that is at least 20 mm longer.
Only use a H05V2V2-F or similar resistance cable to the maximum
temperature of 90°C. Its replacement must be carried out be a specialised
technician who must carry out the network connection following the
diagram below.
L = brown
N = blue
= yellow-green
The manufacturer declines all responsibility for damage to persons or
things caused by the non-observance of the above indications or as a
result of tampering with any part of the appliance.