Southbend EZ-3 Electric Steamer User Manual


 
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATORS MANUAL 1178387 REV 2PAGE 19
TROUBLESHOOTING
"Check Water Level" Light Does Not Come On When Unit Runs Out of Water
"CHECK WATER LEVEL" light does not
come on when unit runs out of water.
Remove wire C17 (EZ-3) or C53 (EZ-5)
from "CHECK WATER LEVEL" light and
check resistance across light terminals.
Is resistance over
100 Kohm?
YesNo
Replace light
Check High Limits
(see Figure 13 on
Page 30) and
replace as needed.