TROUBLESHOOTING MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
PAGE 26 OPERATOR’S MANUAL 1178387 REV 2
TROUBLESHOOTING
Figure 9
Idle Element Resistance Check
Idle Element Plug
Model EZ-3
Model EZ-5
High Limit
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Disconnect idle element plug (PL3).
4. Place test leads as shown above.
5. Check to see if resistance is within +/- 10% of values in the following table:
Voltage
Model EZ-3
Resistance (Ohms)
Model EZ-5
Resistance (Ohms)
208 115 87
220 129 97
240 154 115
380 385 289
415 459 344
480 614 461
6. Remove one test lead, place on ground, check for short circuit.