Southbend EZ-3 Electric Steamer User Manual


 
TROUBLESHOOTING MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
PAGE 32 OPERATORS MANUAL 1178387 REV 2
TROUBLESHOOTING
Figure 15
Controller Check (EZ-5 only)
C98
1. Disconnect power at circuit breaker.
2. Remove control panel, but leave plugged in.
3. Disconnect wire C98 from controller.
4. Reconnect power.
5. Use a spacer to hold door switch in closed position. Contactor should actuate and then deactuate
in less than 60 seconds.
6. If contactor fails to actuate (or actuates but fails to deactuate), replace controller.
7. With spacer still in place and door open, momentarily reconnect wire C98 and then disconnect.
8. Controller should actuate, then deactuate 10 seconds after C98 is disconnected.
9. If contactor fails to actuate (or actuates but fails to deactuate), replace controller.