Southbend EZ-3 Electric Steamer User Manual


 
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATORS MANUAL 1178387 REV 2PAGE 25
TROUBLESHOOTING
Figure 8
Contactor Coil and MOV Check
A
B
C
D
E
F
Actuator
MOV
TOP VIEW
LEFT SIDE VIEW
1. Disconnect power at circuit breaker.
2. Remove control panel and disconnect nine-pin plug PL1.
3. Depress actuator on top of contactor. Actuator should travel freely and spring back when released.
4. Check for continuity between contacts A and D as shown in top view. There should be no
continuity.
5. Repeat Step 4 for contacts B and E and for contacts C and F.
6. Place test leads on contactor coil terminal as shown in left side view.
7. Check resistance.
8. If resistance is not approximately 390 (+/- 40) ohms, remove MOV and recheck coil resistance. If
resistance is now approximately 390 (+/-40) ohms, replace MOV, otherwise replace contactor.
9. Reconnect all wires.