Southbend EZ-3 Electric Steamer User Manual


 
TROUBLESHOOTING MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
PAGE 28 OPERATORS MANUAL 1178387 REV 2
TROUBLESHOOTING
Figure 11
Door Switch Continuity Check
Terminal Block
Door Switch
Model EZ-3
Model EZ-5
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.
4. EZ-3: Remove door switch lead wires from terminal block positions 2 and 3, or
EZ-5: Remove door switch lead wires from terminal block position 1 and terminal 2 of the controller.
5. Place test lead as shown inside the terminal connectors of the lead wires.
6. Check for continuity - (there should be NO continuity).
7. Depress door switch actuator rod and check for continuity - (there should be continuity).