Sub-Zero 427G Refrigerator User Manual


 
Models 427G and 427RG Installation 18
Electrical Requirements
F
or models 427G and 427RG, the electrical supply should
be located within the shaded area shown in the illustration
below. Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE: For models 427G and 427RG, the
electrical outlet must be placed so the grounding prong is
to the right of the thinner blades. The outlet must be flush
with the back wall.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician
to be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.