Models 427 and 427R Installation 18
Electrical Requirements
F
or models 427 and 427R, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE: For models 427 and 427R, the elec-
trical outlet must be placed so the grounding prong is to
the right of the thinner blades. The outlet must be flush
with the back wall.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
13"(330)
1
/4"
(
6)
4
1
/2"
(
114
)
LEFT SIDE
OF OPENING
FLOOR
2
1
/2"
(64)
FRONTVIEW
Location of electrical supply.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do not
remove the power cord ground prong.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity and is
properly grounded.