Home Alarm Connections
I
f a home alarm system is to be installed on the wine
storage unit, the connections should be made using the
logic supplied with the alarm specifications. Refer to the
illustration for the appliance lead locations, and refer to
the following for color codes:
• Normally open contacts – white with red stripe wire
• Normally closed contacts – white with blue stripe wire
• Common – gray with white stripe wire
Use the
1
/4" (6) spade terminals or wire nuts provided to
make the proper wiring connections.
IMPORTANT NOTE: If you are not responsible for alarm
system connection, this information should be supplied to
the home security system contractor.
Model WS-30 Installation 42
ANCHORING
SCREWS
Top anchoring. Bottom anchoring.
ANCHORING
SCREW
Anchoring
A
fter door and side panels have been installed, the unit
has been leveled and door adjustment completed, anchor
the wine storage unit to the opening. This will assure a
proper fit and a secure installation.
IMPORTANT NOTE: Be sure to level and square the unit
before anchoring it.
To anchor the unit to cabinetry, open the grille, and install
the screws provided through the grille frame into the cabi-
netry. There are several hole locations provided. Check for
proper door clearance by fully opening the door. Refer to
the illustration below.
Next, drill a screw through the side hole inside the roller
base assembly. There is one on each side. The screw will
need to go in at an angle in order to attach properly.
In a flush inset application, additional material may be
needed behind the cleat to ensure sufficient anchoring.
If the screws provided are not suitable for your
application, you must provide adequate screws.
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power.
Any unused terminals should be completely insulated
and all wires should be secured away from conductive
or moving components.
HOME ALARM
CONNECTIONS
Home alarm connections.