Taylor 390 Freezer User Manual


 
3
Model 390 To the Installer
130916
S Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnect ing device with a contac t gap of
at least 3 m m installed in the external
installati on.
S Appliances that ar e permanently connect ed
to fixed wiring and for w hich leakage
current s may exceed 10 mA , particularly
when disconnected, not us ed for l ong
periods, or during i nitial installation, shall
have protective dev ices such as a GFI to
protect against the leakage of current,
installed by authorized per sonnel to the local
codes.
S Supply cords used with this unit shall b e
oil-resistant , sheathed flexible c able, not
lighter than ordinary polychloroprene or
other equivalent synthet ic
elastomer-sheathed cord (Code designation
60245 IE C 57) inst alled with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the c onductors from
abrasion.
If the supply cord is dam aged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
Beater r otation must be clockwise as viewed
looking into the freezing cylinder of the freezer.
Note: The following procedures should be
performed b y a tr ained service technician.
To correct the rot ation on a three- phase unit,
interchange any two incoming power s upply lines at
the freezer main terminal block only. To correct rotation
on a single- phas e unit , change the leads ins ide the
beater motor. (Follow diagram printed on m otor.)
Electr ical connections are made directly to the
terminal block. The terminal block is l ocated in the
control box located behind the left side panel.
Refriger ant
In consideration of our environment, Taylor
uses only earth friendly HFC refr igerants. The HFC
refrigerant used in this unit is R404A. This refr igerant
is generally considered non-t oxic and non-f lammable,
with a n Ozone Depleting Potential (ODP) of zero (0).
However , any gas under pressure is potentially
hazardous and must be handled with caution. NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal e xpansion.
Use only R404A refrigerant that conforms to
the AHRI standard 700 specification. The use of any
other refrigerant m ay expose users and operators to
unexpected s afety hazards.
Refrigerant liquid spr ayed onto the s kin may
cause serious damage to tiss ue. Keep eyes and skin
protected. If refrigerant bur ns should occur , flush
immediately with cold water. If burns are severe, apply
ice pac ks and c ontact a physician immediately.
Taylor reminds te chnicians t o be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
fact ory Service Department.
W ARNING: R404A refrigerant used in
conjunction with polyolester oils is extr emely moist ure
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to pr event humid air or
water from being absorbed by the oil.