Taylor C712 Freezer User Manual


 
26
Model C712Operating Procedures
Step 20
Install the front drip tray and splash shield under the
door spouts. (See Figure 49.)
Figure 49
Mix Pump Assembly
Step 1
Inspect the rubber pump parts. O-rings and gasket
must be in 100% good condition for the pump and
entire machine to operate properly. The o-rings and
gasket cannot properly serve their intended function
if nicks, cuts, or holes in the material are present.
Replace any defective parts immediately and
discard the old.
Step 2
Assemble the piston. Slide the red o-ring into the
groove of the piston. DO NOT lubricate the o-ring.
(See Figure 50.)
Figure 50
Step 3
Apply a thin layer of lubricant to the inside of the
pump cylinder at the retaining pin hole end. (See
Figure 51.)
Figure 51
Step 4
Insert the piston into the retaining pin hole end of the
pump cylinder. (See Figure 52.)
Figure 52
Step 5
Assemble the valve cap. Slide the o-ring into the
groove of the valve cap. DO NOT lubricate the
o-ring. (See Figure 53.)
Figure 53