30
Model C712Operating Procedures
Step 11
With an empty pail beneath the door spouts, raise
the prime plug and touch the PUMP symbol
.
Step 12
When a steady stream of sanitizing solution is
flowing from the prime plug opening in the bottom of
the freezer door, open the draw valve. Momentarily
open the center draw valve to sanitize the center
door spout. Draw off the remaining sanitizing
solution.
Step 13
Once the sanitizer stops flowing from the door
spout, touch the WASH and PUMP symbols
and close the draw valve.
Repeat these steps for the other side of the
machine.
Note: Be sure your hands are clean and
sanitized before going on in these instructions.
Priming
Note: Use only FRESH MIX when priming the
freezer.
Step 1
Place an empty mix pail beneath the door spouts.
With the prime plug in the UP position, pour 2-1/2
gallons (9.5 liters) of FRESH mix into the mix hopper
and allow it to flow into the freezing cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Step 3
Once a steady stream of mix starts to flow from the
prime plug opening in the bottom of the freezer door,
push the prime plug down.
Step 4
When mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump. Insert the outlet end of the mix
feed tube into the mix inlet hole in the mix hopper.
Place the inlet end of the mix feed tube into the
outlet fitting of the mix pump. Secure with cotter pin.
Step 5
Select the AUTO symbol
.
Note: The brush clean counter will start at this time.
Step 6
Fill the hopper with fresh mix and place the mix
hopper cover in position.
Repeat these steps for the other side of the
machine.
Manual Brush Cleaning
This Procedure Must Be Completed Every Day
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble the Model C712, the following items
will be needed:
S Two cleaning and sanitizing pails
S Sanitizer/Cleaner
S Necessary brushes (provided with freezer)
S Single service towels
Draining Product From The
Freezing Cylinder
Step 1
With a pail beneath the door spouts, open the draw
valve. Touch the WASH and PUMP symbols
.
IMPORTANT! DO NOT allow the pump to keep
running when the draw valve is closed.
Excessive pressure will build up causing
product to spurt out when the draw valve is
opened.
Drain the product from the freezing cylinder and the
mix hopper.
Step 2
When the flow of product stops, touch the WASH
and PUMP symbols
, cancelling the WASH
and PUMP modes. Close the draw valve and push
the prime plug down.
Step 3
Remove the cotter pin, mix feed tube, pump clip and
the assembled air/mix pump.
Repeat these steps for the other side of the
machine.