From Control
Panel
Motor connector
VTN 420 or VTN 620
Wiring the HOOD with an
IntegralVentilator:
Warning: Turn off electricity at
the service panel before wiring the
unit.
1. Connect the Integral Ventilator
molex plug connector to the
connector present inside the
hood as shown in Figure 9 or
Figure 10.
2. Remove the j-box cover as
shown in Figure 11.
3. Remove 1 of 2 knockouts and
install 1/2 conduit connector
in j-box.
4. Run black, white, and green
wires (#14 AWG) in 1/2 conduit
from power supply to j-box.
5. Connect black, white, and
green wires from power supply
to black, white, and green/
yellow wires in j-box
respectively.
6. Close j-box cover.
Final installation steps
7. Only HSB30 and HS30 Series
hoods: fit the side mould on the
right side, and fix it with 3
screws as shown in Figure 12.
8. Replace filters as described in
the Care & Use section of this
manual.
Turn power on at service panel.
Check operation of the hood.
Figure 10