VII. p - ADJUSTING THE ROOM TEMPERATURE OFFSET:
The room temperature offset parameter allows a service technician or end user the ability to have the
display show a temperature that is within three degrees of the actual temperature being read by the
cabinet air sensor. This allows for continuity of reading between different temperature reading devices.
(i.e.: thermistor Vs thermocouple Vs handheld thermometer) This parameter is preset at the factory to
“0” or no offset.
Follow the instructions to enter the customer access code on page 9. When the control displays
Thermostat Set High, press the down arrow key until the control display reads
Room Temperature Offset. Press the set button . Use the arrow keys to adjust the
offset to your desired setting. When the display shows the offset you want press the set button .
The display will then read Thermostat Set Point High. You can use the up or down arrow
keys to scroll to the next parameter or press the alarm cancel button to exit .
-17-
VII. INTELA-TRAUL
®
(continued)
SET
SET
)
)
)
VII. q - SETTING THE AUDIBLE ALARM STYLE:
This parameter will allow the customer to turn on/off the audible alarm feature on the INTELA-
TRAUL
®
control. The audible alarm is preset from the factory to OFF. The customer can choose
between an audible alarm that sounds for 3 seconds then automatically turns off, or a continuous
audible alarm that must be manually acknowledged. Regardless of this feature’s setting, visual alarm
text will display when conditions warrant.
To adjust this setting, follow the instructions to enter the customer access code on page 9. When the
control displays Thermostat Set Point High, press the up arrow key until the display
reads Audible Alarm Style. Press the set button . The display will read OFF.
Use the arrow keys to scroll between for the 3-Second Audible Alarm Burst or
for Continuous Audible Alarm. When the display shows your choice of style, press the set
button . The display will then read thermostat Set Point High. Use the arrow keys
to scroll to the next parameter or press the Alarm Cancel Button to exit.
SET