............ www.truemfg.com ............
True Food Service Equipment, Inc.
15
15
MAINTENANCE, CARE & CLEANING
TEMPERATURE CONTROL ADJUSTMENT FOR
HIGH ALTITUDE ONLY!
TERMS:
• Cut-out - Temperature sensed by the controller
that shuts the compressor off.
• Cut-in - Temperature sensed by the controller
that turns the compressor on.
TOOLS REQUIRED:
• Phillips head screwdriver
•
5
/64" or 2 mm Allen wrench
• T-7 Torx wrench
A. Unplug or disconnect power to the cabinet.
B. Remove the screws that secure the tempera-
ture control to the inset box, lower right, rear
of cabinet.
C. Pull out gently from cabinet.
NOTE
Mechanical temperature controllers are affected
when functioning at high altitude. The Cut-in and
cut-out temperatures will be colder than when the
controller functions closer to sea level.
D. For high elevation installations, it may be nec-
essary to "warm-up" the set points. To make
the adjustment, insert the appropriate tool in
each adjustment screw and turn 1/4 of a revo-
lution clockwise (to the right). This procedure
will adjust both the cut-in and cut-out about
2°F warmer.
E. Make sure to reconnect the wire to proper
spade terminal when reinstalling.
DANFOSS TEMPERATURE CONTROL
4
3
Cut-out Adjustment Screw
Allen (
5
/64" or 2 mm)
(clockwise for warmer)
Cut-in Adjustment Screw
Torx (T-7)
(clockwise for warmer)
Compressor Connection
(double terminal)
Compressor
Connection