True Manufacturing Company TCGR-77 Refrigerator User Manual


 
............ www.truemfg.com ............
True Food Service Equipment, Inc.
6 6
INSTALLATION / OPERATION INSTRUCTIONS
Step 4
NOTE
Hard wiring for a 30 amp circuit is required on spe-
cific Bakery Cases.
A. Before your new unit is connected to a power
supply, check the incoming voltage with a volt-
meter. If anything less than 100% of the rated
voltage for operation is noted, correct immedi-
ately.
B. Models equipped with 9 ft. (3 m) power cord
must be powered at proper operating voltage at
all times.
Refer to cabinet data plate for voltage.
True requires that a sole use circuit be dedicated
for the unit.
WARNING
Compressor warranties are void if compressor burns
out due to low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove lower rear
grill. Wiring diagram is positioned on the ballast box
inside lower rear of the cabinet.
ELECTRICAL INSTRUCTIONS