U-Line 2275DWRWOL Refrigerator User Manual


 
3-60
Section 3 - Service and Repair
Figure 65
Figure 66
IMPORTANT
IMPORTANT
Before installing your U-Line unit with factory- installed U-
Line P60 pump, it is extremely important to check and test
all hose connections at the drain pump. There is a possibility
that hose connections may have loosened during shipment.
WARNING
To prevent accidental electrocution, make certain that
the floor surfaces surrounding the unit are dry whenever
power is removed from, or applied to, the unit.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical outlet.
2. Carefully push the power cord grommet through the hole in the
back panel
(Figure 67)
.
Figure 67
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your hands
inside the ice maker cabinet or attempt to touch any
components except the discharge tube during testing.
Failure to follow this warning could result in serious
personal injury or death.
4. Check that the clamps and hose connections are tight at the
following areas
(Figure 68)
:
Discharge tube (A)
Drain tube (B)
Vent tube (C)
Figure 68
5. Place a suitable container beneath the pump’s discharge tube. (The
bucket must be able to hold a minimum of one gallon.)
6. Plug the ice maker power cord into a properly grounded, polarized
electrical outlet.
7. Verify pump operation by pouring one gallon of water into the ice
storage bin of the ice maker. The pump should energize and pump
the water into the container.
8. At this time, verify that all tube and clamp connections are tight
and leak free.
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
Shut-Off
Valve
Disposal Assembly
ULIN_0572_A
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
Spigot Assembly
ULIN_0573_A
Power
Cord
Grommet
Drain
Fitting
Back
Panel
Water
Connection
Screws
ULIN_0574_A
Back View Side View
BB
A
CC
ULIN_0575_A