1. Set the cycle selector switch
to OFF and allow the ice to
melt off of the evaporator.
2. Remove all ice from the
storage bin.
3. Remove inside front cover
(see Figure 33).
4. Remove the overflow tube by
lifting it up while using a
slight back and forth motion
to loosen it from the drain
hole (see Figure 34). The
water in the reservoir will
flow down the drain.
5. Replace the overflow tube
after all of the water has
drained from the reservoir.
6. Move the cycle selector
switch to the CLN position.
7. When water begins to flow
over the evaporator (approx-
imately 3 minutes), add one
package of U-Line Ice
Machine cleaner to the
water reservoir.
8. Reinstall inside front cover.
9. When the self-cleaning
process stops (approximately
45 minutes) it may be desirable to clean the storage bin at this
time (see INTERIOR CLEANING).
10. Move the cycle selector switch to the ICE/ON position to resume
ice production.