Problem Possible Cause Remedy
Unit runs but Scale and mineral Clean unit. See
produces very buildup in unit. MAINTENANCE.
little ice.
Inadequate airflow at Remove items blocking
(continued)
the front of the unit. airflow.
Ice is slow to Ice-making system Run unit through
release or does is dirty. automatic clean cycle.
not release from See MAINTENANCE.
the evaporator.
Unit is not level. See LEVELING THE
UNIT.
Low air temperature Surrounding air
around unit. temperature must be
at least 50°F (10°C).
Poor ice quality. Poor incoming water Consult a qualified
(soft or unclear) quality. plumber to test the
water quality and
recommend appropriate
treatment.
Ice-making system is Run unit through
dirty. automatic clean cycle.
See MAINTENANCE.
Unit produces Low water level. Check to see that
shallow or overflow tube is fully
incomplete cubes, seated.
or the ice fill
pattern on the Hot incoming water. Connect the unit to a
evaporator is cold water supply.
incomplete. See INSTALLATION.
Incorrect incoming Water pressure must
water pressure. be 20-120 psi.
Unit is not level. See LEVELING THE
UNIT.
Body_UM.qxd 12/17/04 9:16 AM Page 37