NOTE
Ice thickness adjustment dial should be turned only one
increment at a time. Allow unit to stabilize for 24 hours
before making further adjustments.
4. Turn ice thickness adjustment dial clockwise for a thicker ice bridge
or counterclockwise for a thinner ice bridge.
5. Reinstall front access panel.
6. Reconnect power.
CARE AND CLEANING
EXTERIOR CLEANING
Periodic cleaning and proper maintenance will ensure efficiency, top
performance, and long life. We suggest the following:
Avoid the use of solvent cleaning agents, abrasives and all cleansers
that may impart taste to the ice cubes. The exterior may be cleaned
with non-abrasive cleansers as used on fine furniture.
CONDENSER CLEANING
Disconnect electric power to the ice maker
before cleaning the condenser.
The condenser fins are SHARP. DO NOT run hands over
condenser fins.
The front grille should be kept free of dust and lint to permit free air flow
to the condenser (see Figure 30). The condenser coil, located behind
the front grille and access panel, should be cleaned three to four times
each year. Use a soft brush or vacuum cleaner to remove dirt, lint
and other accumulations from the condenser coil. Clean from top to
bottom, not side to side. Be careful not to bend the condenser fins.
!
CAUTION
!
WARNING
!
23