U-Line CLR60 Ice Maker User Manual


 
5. Place a suitable container beneath the pump’s discharge tube.
(The bucket must be able to hold a minimum of one gallon.)
Back panel serves as a guard. DO NOT put your hands
inside the ice maker cabinet or attempt to touch any com-
ponents except the discharge tube during testing. Failure
to follow this warning could result in serious personal
injury or death.
6. Plug the ice maker power cord into a properly grounded, polarized
electrical outlet.
7. Verify pump operation by pouring one gallon of water into the ice
storage bin of the ice maker. The pump should energize and
pump the water into the container.
8. At this time, verify that all tube and clamp connections are tight
and leak free.
9. Unplug unit power cord from electrical outlet.
10. Leave back panel off for water line installation.
11. Continue to the next step in the installation process, SITE PREPA-
RATION.
CONNECTING A DRAIN PUMP
Connecting A Drain Pump
If a gravity drain connection is not available, and you have not pur-
chased the CLR60 with factory installed pump, install the U-Line P60
drain pump in the rear compartment of the ice maker. The U-Line P60
drain pump is available through your Dealer, or direct from U-Line with
complete installation instructions.
If a gravity drain connection is not available, and you have not pur-
chased the CLR60 with factory installed pump, U-Line strongly rec-
ommends the use of the U-Line P60 drain pump. If a pump other
than the U-Line P60 drain pump is to be used, it must meet the fol-
lowing specifications:
It must be UL listed and have a UL listed, 120 VAC, 3-wire ground-
ed power cord.
!
WARNING
!
7