CLR2160, CLRCO2175 13
Figure 9
1. Turn the ice maker off (allowing any ice to melt off of
the evaporator) as follows:
a. Touch and hold the ON/OFF button (Figure 9, 1).
b. The display (Figure 9, 3) will switch from ICE to OFF
to confirm that the ice maker is off.
2. Remove all ice from the storage bin.
Figure 10
3. Remove inside front cover
(Figure 10, 1)
.
Figure 11
4. Remove the overflow tube
(Figure 11, 1)
by lifting it
up while using a slight back and forth motion to loosen
it from the drain hole. The water in the reservoir will
flow down the drain.
5. Replace the overflow tube after all of the water has
drained from the reservoir.
6. Start the cleaning cycle as follows:
a. Touch and hold the ON/OFF button (Figure 9, 1).
b. Touch and release the LIGHT button (Figure 9, 4)
three times, then release the ON/OFF button
(Figure 9, 1).
c. The display (Figure 9, 3) will show “CL” to confirm
the beginning of the cleaning cycle.
7. When water begins to flow over the evaporator
(approximately three minutes), add one package of U-
Line Ice Machine cleaner to the water reservoir.
8. Reinstall inside front cover.
9. When the self-cleaning process stops (approximately 45
minutes) the unit will remain off for an additional 15
minutes. When clean cycle is completed, display will
automatically switch back to set temperature and unit
will run as normal operation.
10.Clean the storage bin (See INTERIOR CLEANING).
Sanitize the bin with a solution of 1 tablespoon of
bleach in 1 gallon of warm water. Rinse thoroughly
with clean water.
11.To ensure that the drain system is working properly,
pour 1 gallon of cool, fresh water into the ice bin. The
water should drain freely. If your unit is equipped with
a drain pump, it should drain the ice bin.
When ice production resumes, the water fill valve will
energize, fill the water reservoir, and shut-off after three
minutes. The compressor begins to operate and water
flows over the evaporator assembly (ice cube tray).
Initially, the water flow may not be uniform, causing
uneven sized cubes or water to spill into the ice storage
bin. This is a normal situation that will correct itself within
the first 24 hours of operation.
IMPORTANTIMPORTANT
• Discard all ice produced in the first harvest.
• Should power to the unit be interrupted during
the self-clean cycle, it will be necessary to repeat
the complete cleaning cycle after power is
restored.
Inlet Screen
Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least
once each year as follows:
1. Shut off the water at the main supply valve.
2. Pull the unit out to access the back panel.
3. Disconnect electrical power to the unit.
123 54
ULIN_0058_A
1
ULIN_0059_A
1