U-Line CLRCO2175 Ice Maker User Manual


 
CLR2160, CLRCO2175 7
Figure 2
IMPORTANTIMPORTANT
Proper air flow (Figure 2) is required for your unit to
operate at its highest efficiently. A grille, located in
the base of the unit, must not be blocked at any
time, or your unit will not perform as expected.
Initial Startup
All U-Line units are shipped with controls that are preset.
No initial adjustments are required.
IMPORTANTIMPORTANT
U-Line recommends the unit be allowed to run
overnight prior to loading the Model CLRCO2175
refrigerator with product.
On ice maker equipped units, it is possible that
dirt or scale will dislodge in the water line.
Always throw away all ice cubes made during the
first two to three hours of operation.
Figure 3
To turn the unit on or off, touch and hold the POWER icon
(Figure 3, 1) on the display panel for approximately five
seconds until the °F symbol flashes and release.
A small LED above the icon will illuminate to confirm
the touch of any controller icon.
The CLRCO2175 display (Figure 3, 3) will show the
unit set-point temperature (38°F) when the unit is on
and will show OFF when the unit is off. The CLR2160
display (Figure 3, 3) will show ICE when the unit is on
and will show OFF when the unit is off.
Turning the unit off will override any other control
function.
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 23.
Water Supply
The unit requires a 1/4-inch OD water supply line and a
shut-off valve. For more information see Page 22.
Drain
The unit’s generous 7-inch drain connection height
extends the distance the unit can be located from a
gravity drain. For more information see Page 19.
IMPORTANTIMPORTANT
Drain can NOT be located directly below unit. Unit
has a solid base that will not allow unit to drain
below itself.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:
The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures and may also reduce the ice
production rate for those models with icemakers.
If the ambient temperature is expected to drop below
45°F (7°C), drain all water from the unit to prevent
freezing damage not covered by the warranty.
For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
For best performance and life outdoors, place under a
counter or provide shelter of some kind.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.