U-Line CLRCO2175 Ice Maker User Manual


 
CLR2160, CLRCO2175 15
Figure 15
A unit that is not level can cause a reduction in ice rate,
uneven sized cubes or water spilling into the storage area,
which will cause the ice in the bin to melt prematurely
(Figure 15).
When checking the level, remember that floors near
drains have a tendency to slope towards the drain.
Figure 16
Use a level to check the levelness of the unit from front to
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 16).
Figure 17
6. If the unit is not level, adjust the feet on the corners of
the unit as necessary
(Figure 17)
.
7. Check the levelness after each adjustment and repeat
the previous steps until the unit is level.
Door Alignment Check and Adjustment
IMPORTANTIMPORTANT
When properly aligned:
The door will not be flush with the top of the
cabinet. The top edge of the door will be 1/8 in.
(3.175 mm) below the cabinet top.
The door gasket will be firmly in contact with the
perimeter of the cabinet and not pinched on the
hinge side of the door.
The following procedure will correct for up to 1/4 in.
misalignment:
Figure 18
1. Compare the top edge of the door (opposite the
hinges) to the top edge of the cabinet (Figure 18) and
note the type (up or down) of adjustment needed.
Figure 19
2. Remove the top hinge pivot pin with a Phillips
screwdriver
(Figure 19)
and lift door off bottom hinge
pin. Be careful not to lose the door closer insert sets.
ULIN_0047_A
1
ULIN_0043_A
1
ULIN_0044_A
1/8"
(3.175 mm)
ULIN_0016_A
ULIN_0133_A