Problem Possible Cause Remedy
The unit is not For model 29AD only:
cold enough is the defrost timer set
(continued) to the correct time of day?
See INITIAL START-UP
The unit is not cold The door was left open Turn off the unit to manually
enough (Frost free causing the evaporator defrost the evaporator.
units only) behind the back wall to See DEFROSTING.
fill with frost preventing
proper air flow and cooling.
The unit frosts Unit is manual Models BI-15, 95, 98,
up defrost model and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING
Door gasket not Adjust door. See
sealing properly ALIGNING THE DOOR
High ambient Defrost unit manually.
temperatures or See DEFROSTING
humidity
Water is leaking Water supply Tighten fitting. See
out the back connection leaking CONNECTING THE
of the unit WATER SUPPLY
Ice cubes Door gasket not Adjust door. See
sticking together sealing properly ALIGNING THE DOOR
Infrequent use of cubes Break apart cubes
Noise during Copper water supply Carefully bend tubing
operation tubing contacting away from cabinet and
internal components components
Fan blade touching Remove obstruction
obstruction (wiring,
foam insulation, etc.)
No ice Bin arm locked in Lower bin arm
upright position
Not enough ice Control set too cold Adjust control to a
warmer setting
(COUNTER-CLOCKWISE)
Ice cube size too Set cube size smaller.
large See ADJUSTING ICE
CUBE SIZE
Water leaks into Water level set too Set cube size smaller.
ice bucket high See ADJUSTING ICE
CUBE SIZE
Fresh food section Ice bucket not fully Push ice bucket
on Combo units inserted into place
too cold
Temperature control Set control to warmer
set too cold setting (COUNTER-
CLOCKWISE)
28