Verona VEFSGE 304 SC.. Range User Manual


 
12
gas connection
2
2. Pressure Regulator:
a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulator
ontheincomingservicelineforsafeandefcientoperation,sinceservicepressure
mayuctuatewithlocaldemand.
Beforeinstallingtheregulatormountthe1/2”NPT(conical)maleconnectortothe
regulator(seepicture2.2).
Gasketsuppliedhastobeplacedbetween1/2”NPT(conical)connector/extension
pipemalepipetting(seepicture2.3).
Theregulatorsuppliedwiththisrangemustbeinstalledbeforeanygasconnections
aremade.
Usesuppliedpressureregulatoronly.
Gas supply line
Shuto valve
“open” position
To range
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Fig. 2.1
Allgasconnectionsmustbemadeaccordingtonationalandlocalcodes.Thisgassupply
(service)linemustbethesamesizeorgreaterthantheinletlineoftheappliance.Sea-
lantonallpipejointsmustberesistanttotheactionofLP/Propanegas.
TherangeisequippedfortheusewithNATURALgas.Itisdesign-certiedbyCSAInter-
nationalforNATURALandL.P.gaseswithappropriateconversion.
Themodel/serialratingplate,locatedinsidethebottompivotingpanel,hasinformation
onthetypeofgasthatcanbeused.Ifthisinformationdoesnotagreewiththetypeof
gasavailable,checkwiththelocalgassupplier.Seepagefrom16to18forL.P.gas
conversioninstructions.
1. Manual Shut-off Valve(g:2.1):
Amanualshut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternal
totheapplianceforthepurposeofturningonorshuttingoffgastotheappliance(InMas-
sachusettssuchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminersof
Plumbers&GasFitters).
Thisvalveshouldbelocatedinthesameroomastherangeandshouldbeinalocation
thatallowseaseofopeningandclosing(inapositionwhereitcanbereachedquicklyin
theeventofanemergency).
Donotblockaccesstotheshutoffvalve.Thevalveisforturningonorshuttingoffgas
totheappliance.