Verona VEFSGE 304 SC.. Range User Manual


 
6
PROXIMITY TO SIDE CABINETS
1. Thisrangemaybeinstalleddirectlyadjacenttoexisting36”(914mm)
highbasecabinets.
Rangedimensions:
• width:29”7/8(759mm)
• depth:24”13/64(614.9mm)
• height(withoutbackguard):MIN35”21/32(905.5mm)-MAX36”
11/32(923mm)
• backguard(height):3”(76mm)
Gas line opening: Wall-37/64”(14.5mm)fromtherightsidetocentre
ofrange;from5”7/16(138mm)to6”1/8(155.5mm)[dependingonfeet
regulation]fromtheoor.
Grounded outlet:shouldbelocated37/64”(14.5mm)fromtheleftside
tocentreofrange;from5”7/16(138mm)to6”1/8(155.5mm)[depen-
dingonfeetregulation]fromtheoor.
2. TherangeCANNOTbeinstalleddirectlyadjacenttosidewalls,tallcabi-
nets,tallappliances,orothersideverticalsurfacesabove36”(914mm)
high.
Theremustbeaminimumof11”13/16(300mm)sideclearancefromthe
rangetosuchcombustiblesurfacesTOTHELEFTorTOTHERIGHT
abovethe36”(914mm)highcountertop.
IMPORTANT: One side (left or right) above the 36” (914 mm) high
countertop must always be kept clear.
Island installation: Theremustbeaminimumof12”(305mm)clearan-
cefromtherearofthebackguardtosuchcombustiblesurfaceonthe
backoftherangeabovethe36”(914mm)highcountertop.
3. Themaximumuppercabinetdepthrecommendedis13”(330mm).Wall
cabinetabovetherangemustbeaminimumof30”(762mm)abovethe
countertopforawidthofminimum30”(762mm):ithastobecentered
withtherange.Sidewallcabinetsabovetherangemustbeaminimum
of18”(457mm)abovethecountertop.
installation
1
Fig. 1.1
3”
(76mm)
MIN35”21/32(905.5mm)
MAX36”11/32(923mm)
24”13/64
(614.9mm)
29”7/8
(759mm)