16
2
Pressure
regulator
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
REGULATOR COVER
CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas.
Selecttheinjectorstobereplacedaccordingtothe“INJECTORSTABLE”.
Thenozzlediameters,expressedinhundredthsofamillimetre,aremarkedonthebodyofeachinjector.
CAUTION: Save the orices removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR
Thepressureregulatorisaccessiblebyopeningthepivotingpanel(g.2.6);thepressureregulatoris
positionedontherearrightsideoftherange(g.2.7).
To set the pressure regulator(g.2.7):
1. Unscrewtheregulatorcover.
2. Unscrewthe“A”component,reverseandscrewitaccordingtotheLP/PROPANE(orNATURALGAS)
regulation.
Fig. 2.6
Fig. 2.7