Viking 15" W Ice Maker User Manual


 
11
DRAIN PLUMBING
Your ice machine uses a gravity drain that requires 5/8” (.63 cm) ID tubing from the back of the
ice maker to a plumbed connection to a sanitary sewer (see Gravity Drain drawing below).
Remove the access panel, with a 5/16” (0.8 cm) wrench to plumb in drain connection. Gravity
drain location for built-in units can be within the area shown in illustration below. An optional
drain pump can be purchased for your ice machine if a gravity drain is not accessible.
Observe and follow all local codes when installing an ice machine.
FFaaiilluurree ttoo uussee aaddeeqquuaattee
ddrraaiinnaaggee ssyysstteemm wwiillll rreessuulltt
iinn ssuurrrroouunnddiinngg wwaatteerr
ddaammaaggee aanndd//oorr ppoooorr iiccee
pprrood
duuccttiioonn..
WARNING
1 1/2" (3.8 cm) DRAIN
PIPE
DRAIN TRAP
5/8" (.63 cm) I.D.
DRAIN TUBING
AND HOSE CLAMP
ICE MAKER
POWER CORD
ACCESS PANEL
DRAIN FROM
ICE MAKER
DRAIN PUMP
DISCHARGE TUBE GOES THRU
THIS OPENING IN THE ACCESS PANEL
VENT TUBE
TUBING CLAMPS
DRAIN PUMP
POWER CORD
DRAIN FROM
ICE MAKER
ACCESS PANEL
VENT TUBE GOES THRU THIS
OPENING}{ IN THE ACCESS PANEL
DRAIN PUMP'S}{ DISCHARGE
LINE THRU}{ THIS OPENING
SUPPLIED SCREWS
GRAVITY DRAIN LOCATION
TToopp ooff
UUnniitt
FFrroonntt ooff
UUnniitt
22” (55.9 cm)
24 5/8” (62.6 cm)
2 3/8” (6.0 cm)
4 1/16”
(10.3 cm)
14 3/4”
(37.5 cm)
6 3/4”
(17.1 cm)
GRAVITY DRAIN
DRAIN PUMP
Model Number - VUIM-DP
((SSoolldd sseeppaarraatteellyy -- sseeee iinnssttaallllaattiioonn
iinnssttrruuccttiioonnss ssuupppplliieedd wwiitthh ddrraaiinn
ppuummpp))
VENT TUBE GOES THRU THIS OPENING
IN THE ACCESS PANEL
DRAIN PUMP’S DISCHARGE
LINE THRU THIS OPENING