Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 Electric Steamer User Manual


 
F35425 (February 2006) Page 10 of 40
1. Drain the generator and allow steamer to cool, if
necessary.
2. Remove rear and side panels as outlined under
COVERS AND PANELS.
3. Disconnect gas line at gas combination control
valve.
4. Disconnect wires to burner assembly.
5. Disconnect wires from gas combination control
valve.
6. Remove the nuts securing the burner to
generator.
7. Drop blower end of burner assembly slightly
down to clear control box and push all wires out
of the way so that burner can be pulled out of
tank.
8. Disconnect wires from the 195°F thermostat
mounted to the generator and operating pressure
switch.
9. Loosen hose clamp attaching lower flexible
water line at back panel and use a wrench to
disconnect barb fitting from main inlet water
connection.
10. Loosen hose clamp attaching upper flexible
water line at back panel and use a wrench to
disconnect barb fitting from main inlet water
connection.
11. Remove water line from generator. Remove
steam hoses from steam trap and supply to
super heater.
12. Disconnect gas tubing from rear panel
13. Remove steel drain tube at tank.
14. Disconnect union between tank and drain.
15. Loosen cable clamp screws securing electrical
cable at rear panel so that cable is free to move.
16. Remove screws to free super heater and lift
super heater off flue pipe.
C24GA SERIES CONVECTION STEAMERS - REMOVAL AND REPLACEMENT OF PARTS