Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 Electric Steamer User Manual


 
F35425 (February 2006)Page 11 of 40
16. Rotate pressure relief valve coupling to allow
pressure relief valve to be rotated about 90° so
that valve is below generator top level.
17. Remove pressure switch from generator.
18. Remove bolts attaching front of generator to
frame.
19. Move any interfering components out of the way,
then push generator slightly forward to disengage
feet and remove generator from rear of cabinet.
20. Reverse procedure to install generator.
FILL AND COLD WATER
SOLENOID VALVES
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Turn off the water supply to the steamer.
2. Remove front and side covers as outlined under
COVERS AND PANELS.
3. Pull the quick connect power leads off the
solenoid valve being serviced.
C24GA SERIES CONVECTION STEAMERS - REMOVAL AND REPLACEMENT OF PARTS