Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 Electric Steamer User Manual


 
F35425 (February 2006) Page 16 of 40
Thumb Wheel Adjustment
The thumb wheel directly below the microswitch
changes both the cut-out (off) and the cut-in (on)
points of the operating Pressure Switch.
Turn the thumb wheel to obtain the proper cut-out (off)
setting. Turning thumb wheel clockwise increases the
pressure. The cut-out (off) off setting should be 3.5 to
4 psi.
Inlet Water/Steam Strainer
1. Unscrew the cap from the body.
2. Remove the screen and any foreign particles
trapped in the opening.
3. Rinse the screen thoroughly to remove
accumulated debris and replace the screen in
the valve body. If the screen cannot be
thoroughly cleaned, replace it with a new one.
4. Reinstall the cap.
C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS