Vulcan-Hart K40GL Hot Beverage Maker User Manual


 
Fig. 13
6. Reverse procedure to install replacement blower
and check for proper operation.
NOTE: Install replacement blower gasket as
necessary.
BURNER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove
BOTTOM COVER.
2. Remove clips securing insulation to bottom of
kettle.
A. Gently remove insulation and save for
reuse.
3. Disconnect spark ignitor lead wires at the ignition
module.
4. Separate compression nuts on gas supply tube.
5. Loosen gas manifold mounting nuts and remove
gas supply tube from the fittings.
Fig. 14
6. Remove combustion chamber cover from bottom
of kettle.
Fig. 15
7. Note alignment of pipe elbow connected to
burner. Remove elbow from burner.
8. Remove burner from combustion chamber cover.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - REMOVAL AND REPLACEMENT OF PARTS
Page 11 of 44 F45461 Rev. A (0713)