Vulcan-Hart K40GL Hot Beverage Maker User Manual


 
Fig. 16
9. Reverse procedure to install replacement burner
and check for proper operation.
Apply pipe thread sealant to burner
threads that is suitable for use with propane gas.
NOTE: Torque mounting nuts for combustion
chamber cover to 30 ft-lb.
SPARK IGNITOR
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove
CONTROL BOX COVER (TILTING) or
CORNER PANEL (STATIONARY).
2. Disconnect spark ignitor lead wires at ignition
module.
3. Remove BOTTOM COVER.
4. Remove clips holding insulation against
combustion chamber cover.
5. Remove spark ignitor from combustion chamber
cover.
Fig. 17
6. Ensure spark gap between ignitor electrode and
ground rod is approximately 1/8". If necessary,
adjust as outline under SPARK IGNITION TEST
Step 8C.
7. Reverse procedure to install and check for proper
operation.
Fig. 18
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - REMOVAL AND REPLACEMENT OF PARTS
F45461 Rev. A (0713) Page 12 of 44