Vulcan-Hart ML-52953 Range User Manual


 
31
STANDARD OVEN PILOT SAFETY VALVE CHECK,
REPLACEMENT (Cont.)
Fig. 37
5. If the millivolt reading is below 5 MV, replace the thermocouple.
6. If the MV reading is within tolerance, the safety valve should be replaced.
SAFETY VALVE REPLACEMENT PROCEDURES
TOOLS REQUIRED:
7
/16" open end wrench,
11
/16" open wrench, and
3
/8" open end wrench.
1. Disconnect unit from main gas supply.
2. Disconnect thermocouple from safety valve (Fig. 38).
Fig. 38