Vulcan-Hart ML-52953 Range User Manual


 
39
CONVECTION OVEN MOTOR AND DOOR SWITCH CHECK,
REPLACEMENT (Cont.)
3. If a short-handled screwdriver is not available, remove (2) screws securing micro switch housing to unit (Fig. 48).
This will allow convenient access to the switch in order to use a standard size screwdriver.
4. Using a screwdriver, remove (2) screws and (2) nuts securing micro switch to housing (Fig. 49).
Fig. 47
Fig. 48