Using a volt meter, measure the voltage (110-120 volts) between Wire #23 and ground, and Wire #22 and ground. If voltage
is present, or if only one wire (#22) has voltage, the centrifugal switch in the motor is bad. The entire motor must be replaced
(see Fig. 65).
NOTE: If line voltage is not present on either of the wires, recheck door switch, power switch and thermostat operation.
CENTRIFUGAL SWITCH CHECK (Cont.)
Fig. 65
REMOVAL OF CONVECTION OVEN SOLENOID
(90 Series Only)
NOTE: This procedure should be done only after the checks for the thermostat, connector pin and centrifugal switch have
been performed.
NOTE: Replacement solenoids come with only one plug. The other plug must be removed from the old solenoid and
reinstalled with the new part.
TOOLS REQUIRED:
11
/16",
1
/2" open end wrenches or 6" adjustable wrench and needle nose pliers.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO
INDICATE YOU ARE WORKING ON THE CIRCUIT.
1. Disconnect unit from main gas and electrical supplies.
2. Disconnect
11
/16" NPT straight fitting (1) at right-hand burner tube, and (2) at the safety valve (Figs. 66, 67, & 68).