SERVICE TECHNICIAN INSTALLATION NOTES
An Ansul® technician must charge and arm the fire suppression system
before the ventilator blower will operate. See page 10.
Installation and start up must be performed by an Authorized
Installation Company.
Installer must complete the WARRANTY REGISTRATION form, and
record appliance installation particulars on the CUSTOMER SERVICE
DATA form in this manual.
Certain codes require cooking equipment to be restrained with a
RESTRAINT DEVICE. It is the RESPONSIBILITY OF THE
INSTALLER to check with the AUTHORITY HAVING JURISDICTION,
in order to ascertain the applicability of this requirement to THIS
SPECIFIC EQUIPMENT INSTALLATION. Any restraint device must
allow access to the back and sides of the unit to provide for servicing
and maintenance, and must not interfere with the operation of the FIRE
SUPPRESSION SYSTEM.
ELECTRICAL INSTALLATION
Refer to the nameplate on the cooking appliance to verify the
ELECTRICAL SERVICE POWER. Voltage and phase must match the
nameplate specifications, and available electrical service amperage
must meet or exceed the specifications listed on page 1. Incoming
wiring must comply with National Electrical Code specifications.
All 3ø fryer / universal hood appliances (except EU units) ship from the
factory with a 3ø cordset.
All 1ø fryer / universal hood appliances; and, all EU fryer / universal
hood appliances must be wired directly to the electrical circuit. Most
jurisdictions require an approved electrical disconnect to be installed in
the branch circuit, in near proximity to the appliance.
Field conversion of 3ø appliances to 1ø is neither recommended nor
authorized by Wells Manufacturing Co.
IMPORTANT!
Verify that this VENTILATOR
and food cooking equipment
installation is in compliance
with the specifications listed
in this manual, with local
code requirements, and in
accordance with N.F.P.A 96
(THE STANDARD FOR
VENTILATION CONTROL
AND FIRE PROTECTION
OF COMMERCIAL
COOKING OPERATIONS -
current edition).
THIS IS THE
RESPONSIBILITY
OF THE INSTALLER
DANGER
ELECTRIC SHOCK
HAZARD
ELECTRIC CONNECTIONS
MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause
death or serious injury.
NOTE: This appliance
requires a dedicated
electrical branch circuit with
50 Amp protection for 3ø; or,
80 Amp protection for 1ø.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
INSTALLATION (continued)
9