Wells WFGA-60FS Fryer User Manual


 
24
B. PROBLEM: BURNERS WONT LIGHT or “POP” WHEN IGNITING
1. Verify that GAS SHUTOFF VALVES (item 20) are in the fully OPEN position.
2. Verify that gas pressure regulators are adjusted to recommended pressure (must be performed
by a qualified technician).
3. Damaged or mis-adjusted internal component(s). Contact a Wells Mfg. Authorized Service
Agency for repairs.
C. PROBLEM: CRADLE LIFT WILL NOT LOWER or
CRADLE LIFT WILL NOT RAISE
1. The CRADLE LIFTmust be lowered manually, but will raise automatically at the end of a cook
cycle. During the period between cook cycles, in the PAUSE mode, or during PRE-HEAT, the
CRADLE LIFT is lowered by pressing
BASKET
, then , and raised by pressing
BASKET
then .
2. The lift motor has a ten second delay (after an up or down command is entered) until it will
accept another command. The lift motor is de-energized during a cook cycle, except when the
PAUSE
key is pressed (see page 12).
3. At the end of a cook cycle, when the time remaining on the READOUT reaches 00:00, the
CRADLE LIFT should raise.
4. If the CRADLE LIFT does not behave as described above, probable cause is a damaged
controller or relay, an internal adjustment, or one or more damaged internal components.
Contact a Wells Mfg. Authorized Service Agency for repairs.
D. PROBLEM: FILTER PUMP WILL NOT RUN
1. Verify that the POWER SWITCH is in the FILTER position.
2. Press the red RESET button (item 17) on the FILTER
PUMP MOTOR, accessible through the front door.
If the pump motor continues to trip out, or if no other
cause is apparent for the pumps failure to run, contact
a Wells Mfg. Authorized Service Agency for repairs.
PUMP MOTOR
OVERLOAD
RESET