SUGGESTIONS ON DIAGNOSIS
IMPORTANT:
1. Check harness connectors for good con-
tact.
2. Before replacing any component verify,
whenever possible, that the component
has proper continuity or resistance values.
There must be proper power to operate the
component.
Display Shows Error Codes
If error codes “C”, “d” or “CF” show in the
display, refer to the “User Interface Failure
Feedback” and “Component Testing” charts
and check out the appropriate compo-
nent(s).
Display Is Normal
Disconnect power for 10 seconds and re-
connect power. If error code is displayed
after 3 minutes, refer to the “User Interface
Failure Feedback” and “Component Test-
ing” charts, and check out the appropriate
component(s).
If no error codes display and a malfunction
is occurring, check or troubleshoot the fol
-
lowing appropriate areas. Also refer to the
“Component Testing” and “Troubleshooting”
charts.
- Electrical system
- Restricted or lack of proper airflow
- Defrost system
- Unusual noises
- Cooling system
Display Is Blank
Refer to “User Interface Failure Feedback”
and “Troubleshooting” charts.