7
Removing the Pump Motor Assembly
1. Unscrew and remove the nozzle cap and remove
the nozzle bearing and spray arm.
(Fig. 2-7)
2. Disconnect the wiring harness from the motor
harness plug.
3. Rubber clamps secure the pump and motor
assembly to the tub. Rotate these inward 90°.
(Fig. 2-8)
4. Remove the drain hose and clamp from the
check valve and unscrew the check valve from the pump.
(Fig. 2-9)
5. Remove the tuned sound absorber. Use an open-end wrench to loosen the shaft from the
motor. Do not loosen the sound absorber by torquing on the large tuned resonator.
-- NOTE --
A small container will be required to catch water from the drain hose after removal.
Fig. 2-7
SPRAY ARM
NOZZLE
CAP
NOZZLE BEARING
6. Remove the pump and motor assembly by pulling up through the inside of the tub.
(Fig. 2-10)
Fig. 2-10
Fig. 2-8
Clamp
Shown Rotated
Inward 90°
Check Valve
Drain Hose
Clamp
Drain
Hose
Fig. 2-9
Tuned
Sound
Absorber