Whirlpool KUIA18NNJ*11 Ice Maker User Manual


 
5-4
Refer to page 4-8 for the procedure for access-
ing the condenser fan motor.
1. Run the diagnostic tests (see page 3-7)
and check for the proper operation of the
condenser fan motor in step 7.
NOTE: During operation, 120 volts will
be present at the condenser fan motor
electrical connector.
CONDENSER FAN MOTOR
WATER LEVEL SENSOR
Refer to page 4-8 for the procedure for access-
ing the water level sensor.
1. Run the diagnostic tests (see page 3-7)
and check for the proper operation of the
water level sensor. in step 4b.
2. With the water level sensor immersed in
water the Service LED should stay on
solid.
3. With the water level sensor out of the water
the Service LED should blink.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
WARNING