Whirlpool RJE-3165 Range User Manual


 
Accessory canning kit (Part No. 242905)
The large diameter of most water-bath or pressure canners com-
bined with high heat settqs for long periods of time can shorten the life
of regular surface units and cause damage to the cooktop.
If you plarl to use the cooktop for canning. we recommend the
installation of a Cannillg Kit Order the kit from your Whirlpool Dealer or
Tech-Care Service Company.
SEE THE “COOKING GUIDE” FOR IMPORTANT CANNING
INFORMATION.
Cleaning and caring for your range
Your range IS designed to be easy to clean You will usually
wipe
off
spills and spatters when they happen. but you will sometimes want to
clean under and behlnd the control knobs and surface units. This sectlon
will tell you how to remove those. and what to use when clean,ng
Removing and replacing surface unit control knobs:
1 Be sxe the control knobs are set to “OFF
2 Pull the black krlobs straight off.
13 If the control has a chrome trim ring. pull it stralyht off
4 Wash the knobs (and trim rings) In warm. sudsy water
5 Replace the trim rings first
If the control spring was removed, put
Pull knob and trim ring
it back exactly as shown on the left.. .small end first.
straight out. Remember
6 Hold the black knob so It points to “OFF“ Push it straight back on
how the spring goes.
Removing and Replacing Oven Control Knobs:
1 Be sure the knobs are set to “OFF.”
2 Pull each knob straight off.
3 Wash the knobs In warm. sudsy klater
_b;
3 The knobs are not Interchangeable Make sure
you put the
adjust-
Terminal
able Oven Temperature Control Knob
on the right place. ,~nd the
crfI!!!e
/
nonadjustable
Oven Selector Knob on the other
\
Removing surface units and reflector bowls:
\
1 F!rst be sure the> Surface Unit Controls are all .‘OFF“ and that the
/ I.
\ I
: 2’
i .”
surface units are cool
Receptacle
2 Lift c-ach surface unrt about an inch (2 5 cm) at the edge ahav from the
plug In (receptacle) Pull the unit straight away from thtj pLllg-ill Do
To
remove
surface
not wmh
surface units. they will burn themselves clea~l durlrly normal
unit, lift and pull
UW
straight out.
.3. Lift out the reflector bowls.