NOTE: Only one of the hinge arms
is spring loaded, which requires use
of the hinge pin for removal. Refer to
the following illustrations for the
location of the hinge pin on various
models.
For 30-inch and 36-inch units, the
hinge pin will be inserted through
the hole in the right hinge arm
(looking at the front of the unit), see
figure 1. On 48-inch and 60-inch
units, the spring hinges are located
on the outside edges of the unit. On
these units, the left oven door will
have the spring hinge on the left
side. The right oven door will have
the spring hinge on the right side.
Refer to figure 2 below.
Oven Door Removal:
• Open the oven door to its fully
opened position.
• Remove the screw and plate.
• Insert the supplied pin (found
taped to inside of oven door)
through hole in the appropriate
hinge arm. See illustration below.
• Lift the oven door to about a 60-
degree angle from the horizontal. Pull
the door away from the oven while
continuing to lift.
• For 48-inch and 60-inch units,
complete this procedure for both the
left and right oven doors.
5
Oven Door Removal
VENTILATION
CONSIDERATIONS
IMPORTANT NOTE: Do not install
or operate your Wolf Dual Fuel Range
without a ventilation hood.
• Start the ventilation hood approxi-
mately five minutes before cooking;
this establishes an air curtain, and
improves the capture of vapor and
moisture.
• Blower requirements may vary due
to length of duct work and number
of angles. The basic recommendation
is 100-150 net CFM per square foot
of cooking area. Consult with your
HVAC representative for more concise
blower requirements.
PLATE
HINGE
PIN
SCREW
PLACE PIN ON
SPRING HINGE SIDE OF UNIT
Figure 1 – Spring Hinge Location
30-inch and 36-inch units
PLACE PINS ON
SPRING HINGE SIDE OF UNIT
Figure 2 – Spring Hinge Location
48-inch and 60-inch units