OVEN
Natural Gas L.P.Gas
Burner Sheet metal construction mounted transversely at rear of oven.
Heat Input 2.4kW (8189 btu/h) 2.4kW(127g/h)
Injector Marking 108 078
Flame Supervision Device Diamond 'H' G.S.D. 100/28 Diamond 'H' G.S.D. 100/30
Thermostat Diamond 'H' 1100/110/B2 Diamond 'H' 1100/114/B2
Thermostat By-Pass Marking 74 79
IMPORTANT - SAFETY REQUIREMENTS
This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current
Editions. Detailed recommendations are contained in the following British Standard Codes of Practice -
BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'.
PROVISION FOR VENTILATION
The room containing the appliance should have an air supply in accordance with BS.5440: Part 2 Current
Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as
well. For room volumes up to 5m
3
an air vent of 100cm
2
is required. For room volumes between 5m
3
and 10m
3
an air vent of 50cm
2
is required. If the room has a door that opens directly to the outside, no air vent is
required. For room volumes that exceed 11m³ no air vent is required. If there are other fuel burning appliances
in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite vent
requirements.
37