7 If the gas supply bayonet and wall fixing bracket are to be located behind the appliance. It must be located
in the shaded area as indicated in Fig.5.
8 Connect flexible hose to the gas inlet supply block see Fig.5 (The flexible supply pipe must be suitable for
use at 70°C above ambient). The hose should be long enough to allow the appliance to be withdrawn
from the cabinet.
9 Position the appliance in front of the cabinet and run the supply cable (See Section 2) through the cabinet
and connect to the junction box or socket. Ensure that the supply is isolated at this stage. Connect
flexible hose to the bayonet connector.
N.B. Two people will be required to carry out the lifting procedure.
Warning: Do not attempt to lift this appliance by the handle.
10 Lift the appliance into the cabinet making sure the hose and supply cable are not trapped. Push the
appliance as far back as it will go.
11 Centralise and fix the appliance using the six wood screws provided, in the position indicated in Fig.4.
12 Carry out a gas soundness check.
NOTE: Check the gas supply pressure before fitting the fascia. (See Section 3).
40
FIXING
POINTS
Fig.4