Connecting the Components
4-556800-A2-GN22-30 January 1997
To establish the connection, perform the following steps:
1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600
card in the host processor.
2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.
3. Connect the 002-0039-0031 connector to the 002-0051-0031 connector.
4. Connect one end of the 035-0152-0031 cable to the 002-0051-0031 connector.
5. Connect the other end of the 035-0152-0031 cable to the terminal port on the StarKeeper.
Connecting Remotely
To connect a remote StarKeeper NMS to the host processor, you will need the following materials:
Two 035-0153-0031 cables
Two 002-0039-0031 connectors
Two DCE devices with the following characteristics:
Asynchronous
Full-duplex
Flow control ON
Bit rates of 1200, 2400, 4800, 9600 bps
Two 002-0050-0031 connectors
Two 035-0152-0031 cables
To establish the connection, perform the following steps at the host processor end:
1. Connect the grounded end of te 035-0153-0031 cable to an available port on the IPC-1600
card in the host processor.
2. Connect the other end of the 035-0153-0031 cable to the 002-0039-031 connector.
3. Connect the 002-0039-0031 connector to the local DCE devices.
Perform the following steps at the remote end:
1. Connect one end of the 035-0152-0031 cable to the terminal port of the StarKeeper.
2. Connect the other end of the 035-0152-0031 cable to the 002-0050-0031 connector.
3. Connect the 002-0050-0031 connector to the remote DCE devices.