A SERVICE OF

logo

PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 75
ReplacingthePumpRelayandCircuitBreaker
ReplacingtheCircuitBreaker
1. Disconnect the connections and power supply
cords from the filter pump.
2. Remove the pump box.
3. Remove the circuit breaker from the pump box.
4. Remove all wires on the circuit breaker using
needle-nose pliers.
5. Squeeze the tabs on the circuit breaker and push
it out.
6. Reinstall the new circuit breaker by following
steps 1 through 5 in reverse.