A SERVICE OF

logo

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A
(Revision Date: Jan. 19, 2006)
6. Real Time Clock: B-SA704-RTC-QM-R
6- 6
10. Pressing the [PAUSE] key enables setting the
Hour.
11. Set the Hour with the [FEED] or [RESTART]
key. Pressing the [PAUSE] key fixes the Hour
and cause the cursor to move to the Minute.
12. Set the Minute with the [FEED] or [RESTART]
key. Pressing the [PAUSE] key fixes the
Minute and cause the cursor to move to the
Second.
13. Set the second with the [FEED] or [RESTART]
key. Press the [PAUSE] key to fix the Second.
Then, the Low Battery Check selection screen
is displayed.
14. Pressing the [PAUSE] key enables choosing
whether to activate the low battery check
function or not. Set the function to ON or OFF
with the [FEED] or [RESTART] key.
ON: Low battery check function is activated.
OFF: Low battery check function is not
activated. (Default)
Press the [PAUSE] key to fix the setting. Then,
the RTC Data Renewal Timing setting screen is
displayed.
15. Pressing the [PAUSE] key enables choosing
the RTC data renewal timing.
16. Choose PAGE or BATCH with the [FEED] or
[RESTART] key.
PAGE: A real time can be printed on each
media. However, the printer needs to
stop the motion before printing each
media to read the real time clock data.
BATCH: Batch print is possible. However, the
same time is printed on the all media
issued in a batch because the real
time clock data is read only for the first
media.
Press the [PAUSE] key to fix the setting. Then,
the current date is displayed.
17. Press the [FEED] and [RESTART] keys at the
same time to return to “<8>RTC SET” display.
<Supplementary Explanation>
1. Be sure to load the battery and set the low battery check function to ON whenever the real time clock is used.
If the battery is not loaded or the battery voltage is low, the real time clock data is erased at the power off time.
2. When the low battery check function is set to ON and if the battery voltage is 2.4V or less, the printer will
result in a “LOW BATTERY” error and stop at the power on time. In that case, hold down the [RESTART] key
to restore to “<1>RESET” display.
3. When “LOW BATTERY” error has occurred, contact the nearest TOSHIBA TEC service representative for
replacement of the battery.
4. If you would like to keep using the same battery even after “LOW BATTERY” error occurs, set the Low battery
check function to OFF, and set the date and time to the real time. As long as the power is on, the Real Time
Clock will function. However, once the power is turned off, the date and time will be reset. Then, please ask
for the battery replacement.
(Continued from the
previous page)
FEED RESTART
PAUSE
<8>RTC SET
TIME H 00
/00/00
PAUSE
Hou
r
FEED RESTART
<8>RTC SET
TIME M 10/00
/00
PAUSE
Minute
FEED RESTART
<8>RTC SET
TIME S 10/30/00
PAUSE
Second
PAUSE
<8>RTC SET
LOW BATT. CHECK
FEED RESTART
<8>RTC SET
LOW BATT. OFF
PAUSE
<8>RTC SET
RENEWAL
FEED RESTART
PAUSE
<8>RTC SET
RENEWAL BATCH
PAUSE
<8>RTC SET
DATE 06/03/01
FEED
RESTART
<8>RTC SET